Structure of the Ribosome with Elongation Factor G Trapped in the Pre-Translocation State (pre-translocation 70S*tRNA structure)
ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 4GD1 | |
| Sample |
|---|
| Pre-translocation ribosome bound to A/P, P/E hybrid state tRNA |
| Sample Components |
| 70S ribosome |
| Transfer RNA |
| Messenger RNA |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK II |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | Freshly glow-disharged grids were loaded into an FEI Mark II Vitrobot and equilibrated to 95% relative humidity at 22 degrees Celsius. 2 microliters o ... |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 85115 |
| Reported Resolution (Å) | 7.6 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | Refinement included data to 12 Angstrom resolution to limit FSC bias. See primary citation Supplementary Information for details. (Single particle det ... |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (4GD1) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | RIGID BODY FIT | ||||
| Refinement Target | Cross-correlation | ||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | REFINEMENT PROTOCOL--rigid body DETAILS--Chain Y not used in refinement | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | FEI FALCON I (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 30 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | 2012-11-02 |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1150 |
| Maximum Defocus (nm) | 6950 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 0.01 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | 133333 |
| Calibrated Magnification | 134615 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| CTF CORRECTION | CTFFIND | 3 |
| MODEL FITTING | CNS | |
| MODEL FITTING | UCSF Chimera | |
| RECONSTRUCTION | EMAN | 2 |
| RECONSTRUCTION | FREALIGN | |
| RECONSTRUCTION | IMAGIC | |
| RECONSTRUCTION | RSAMPLE | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| CTFFIND3, FREALIGN per micrograph | ||||














