Bovine Cardiac Myosin in Complex with Chicken Skeletal Actin and Human Cardiac Tropomyosin in the Rigor State
ELECTRON MICROSCOPY
| Sample |
|---|
| Helical complex of bovine S1 cardiac myosin and human cardiac tropomyosin-decorated chicken skeletal actin filaments |
| Sample Components |
| skeletal actin filaments |
| S1 cardiac myosin |
| cardiac tropomyosin |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | HELICAL ARRAY |
| Vitrification Instrument | FEI VITROBOT MARK III |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | Thin filaments were reconstituted by first mixing F-actin and tropomyosin to final concentrations of 10 uM actin and 7 uM tropomyosin. Just before app ... |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | HELICAL |
| Number of Particles | 32158 |
| Reported Resolution (Å) | 4.24 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | Performed in the Relion post-processing step |
| Refinement Type | |
| Symmetry Type | HELICAL |
| Axial Symmetry | C1 |
| Axial Rise | 27.5 |
| Angular Rotation | -166.4 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (6KN8, 3I5G) | 2 | 3 | ||
| Refinement Space | REAL | REAL | REAL | ||
| Refinement Protocol | FLEXIBLE FIT | OTHER | OTHER | ||
| Refinement Target | |||||
| Overall B Value | 70.88 | ||||
| Fitting Procedure | flexible fitting | real space refinement | manual refinement | ||
| Details | version 1.9.3; initial flexible fitting to align secondary structure using MDFF | version 1.18-3861 | manual refinement of residues to match backbone and sidechain density and to limit clashes, sidechain outliers, and Ramachandran outliers | ||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 53 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1500 |
| Maximum Defocus (nm) | 2500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | |
| Calibrated Magnification | 130000 |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | RELION | 3.0.7 |
| IMAGE ACQUISITION | EPU | |
| CTF CORRECTION | CTFFIND | 4.1 |
| INITIAL EULER ASSIGNMENT | RELION | 3.0.7 |
| FINAL EULER ASSIGNMENT | RELION | 3.0.7 |
| RECONSTRUCTION | RELION | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 45040 | |||