8V8T | pdb_00008v8t

Asymmetrical subunit from a Drp1 lattice on PA nanotubes


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d6.3827
f_angle_d0.3293
f_chiral_restr0.0363
f_plane_restr0.0024
f_bond_d0.0012
Sample
Tetramer complex of Drp1 from a lattice
Specimen Preparation
Sample Aggregation StateHELICAL ARRAY
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles13215
Reported Resolution (Å)14.73
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeDIRECT ELECTRON DE-64 (8k x 8k)
Electron Dose (electrons/Å**2)58.49
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONLeginon3.3
MODEL FITTINGMDFF
INITIAL EULER ASSIGNMENTRELION
FINAL EULER ASSIGNMENTcisTEM
RECONSTRUCTIONcisTEM
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION