ELECTRON MICROSCOPY
Refinement
RMS Deviations | |
---|---|
Key | Refinement Restraint Deviation |
r_long_range_B_other | 58.818 |
r_long_range_B_refined | 58.815 |
r_scangle_other | 52.906 |
r_mcangle_it | 37.316 |
r_mcangle_other | 37.316 |
r_scbond_it | 35.147 |
r_scbond_other | 35.141 |
r_mcbond_it | 26.542 |
r_mcbond_other | 26.541 |
r_dihedral_angle_3_deg | 13.872 |
Sample |
---|
CryoEM structure of the human INO80 core-nucleosome complex state N-6 |
Sample Components |
Histone Octamer |
Synthetic deoxyribonucleic acid |
Specimen Preparation | |
---|---|
Sample Aggregation State | PARTICLE |
Vitrification Instrument | LEICA EM GP |
Cryogen Name | ETHANE |
Sample Vitrification Details |
3D Reconstruction | |
---|---|
Reconstruction Method | SINGLE PARTICLE |
Number of Particles | 82269 |
Reported Resolution (Å) | 3.47 |
Resolution Method | FSC 0.143 CUT-OFF |
Other Details | |
Refinement Type | |
Symmetry Type | POINT |
Point Symmetry | C1 |
Map-Model Fitting and Refinement | |||||
---|---|---|---|---|---|
Id | 1 | ||||
Refinement Space | RECIPROCAL | ||||
Refinement Protocol | FLEXIBLE FIT | ||||
Refinement Target | MAXIMUM LIKELIHOOD WITH PHASES | ||||
Overall B Value | |||||
Fitting Procedure | |||||
Details |
Data Acquisition | |||||||||
---|---|---|---|---|---|---|---|---|---|
Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
Electron Dose (electrons/Å**2) | 1.029 |
Imaging Experiment | 1 |
---|---|
Date of Experiment | |
Temperature (Kelvin) | |
Microscope Model | TFS KRIOS |
Minimum Defocus (nm) | 1100 |
Maximum Defocus (nm) | 2900 |
Minimum Tilt Angle (degrees) | |
Maximum Tilt Angle (degrees) | |
Nominal CS | 2.7 |
Imaging Mode | BRIGHT FIELD |
Specimen Holder Model | |
Nominal Magnification | |
Calibrated Magnification | |
Source | FIELD EMISSION GUN |
Acceleration Voltage (kV) | 300 |
Imaging Details |
EM Software | ||
---|---|---|
Task | Software Package | Version |
PARTICLE SELECTION | cryoSPARC | 4.5.3 |
CTF CORRECTION | cryoSPARC | 4.5.3 |
MODEL FITTING | Coot | 0.9.8.93 |
MODEL FITTING | ISOLDE | 1.8 |
MODEL REFINEMENT | REFMAC | 5.8.0425 |
INITIAL EULER ASSIGNMENT | RELION | 4.0 |
FINAL EULER ASSIGNMENT | RELION | 4.0 |
RECONSTRUCTION | cryoSPARC |
Image Processing | ||||
---|---|---|---|---|
CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
PHASE FLIPPING AND AMPLITUDE CORRECTION | Minimum particle diameter (A) = 120 Maximum particle diameter (A) = 240 |