ELECTRON MICROSCOPY
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| r_dihedral_angle_2_deg | 33.5 |
| r_dihedral_angle_3_deg | 19.492 |
| r_dihedral_angle_1_deg | 18.535 |
| r_dihedral_angle_4_deg | 15.808 |
| r_lrange_it | 9.481 |
| r_lrange_other | 9.481 |
| r_mcangle_it | 4.278 |
| r_mcangle_other | 4.278 |
| r_paralell_plane_angle_deg | 4.002 |
| r_scangle_it | 3.916 |
| Sample |
|---|
| Yeast Mitochondrial Large Ribosomal Subunit |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK II |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | Blot 2.5 seconds before plunging into liquid ethane (FEI VITROBOT MARK II) |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 47124 |
| Reported Resolution (Å) | 3.2 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | A newly developed statistical movie processing approach was used to compensate for beam-induced movement. |
| Refinement Type | HALF-MAPS REFINED INDEPENDENTLY |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | |||||
| Refinement Protocol | |||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | FEI FALCON II (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 25 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | 2013-05-25 |
| Temperature (Kelvin) | 85 |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1200 |
| Maximum Defocus (nm) | 4700 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | 59000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details | Objective lens astigmatism was corrected at 59,000 times magnification |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| CTF CORRECTION | CTFFIND | 3 |
| RECONSTRUCTION | RELION | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| Each particle | ||||