Head region of the closed conformation of the human type 1 insulin-like growth factor receptor ectodomain in complex with human insulin-like growth factor II.
ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 5U8R | |
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| f_dihedral_angle_d | 18.215 |
| f_angle_d | 0.739 |
| f_chiral_restr | 0.05 |
| f_plane_restr | 0.006 |
| f_bond_d | 0.005 |
| Sample |
|---|
| Head region of the close-leg conformation of the human type 1 insulin-like growth factor receptor ectodomain in complex with human insulin-like growth factor II. |
| Sample Components |
| Insulin-like growth factor 1 receptor |
| Insulin-like growth factor II |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 108899 |
| Reported Resolution (Å) | 3.7 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (5U8R) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | FLEXIBLE FIT | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | UCSF Chimera was used for the initial fitting and ISOLDE v 1.03b was using for flexible fitting. | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 50 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | |
| Maximum Defocus (nm) | |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | RELION | 3.0.5 |
| IMAGE ACQUISITION | EPU | |
| CTF CORRECTION | CTFFIND | 4.1.13 |
| MODEL REFINEMENT | PHENIX | 1.16 |
| INITIAL EULER ASSIGNMENT | cryoSPARC | 2.11 |
| FINAL EULER ASSIGNMENT | cryoSPARC | 2.11 |
| CLASSIFICATION | cryoSPARC | 2.11 |
| RECONSTRUCTION | cryoSPARC | 2.11 |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 2057701 | |||