SP6-11 biased agonist bound to active human neurokinin 1 receptor in complex with miniGs/q70
ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 6HLP | |
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| f_dihedral_angle_d | 12.6813 |
| f_angle_d | 0.8422 |
| f_chiral_restr | 0.0525 |
| f_plane_restr | 0.0066 |
| f_bond_d | 0.0042 |
| Sample |
|---|
| Substance P bound to Neurokinin 1 receptor-miniGs/q70 complex |
| Sample Components |
| Guanine nucleotide-binding protein G(s)/G(q) subunit alpha hybrid |
| Guanine nucleotide-binding protein G(I)/G(S)/G(T) subunit beta-1/gamma-2 |
| Substance-P receptor |
| Substance P 6-11 |
| Nanobody 35 |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 59926 |
| Reported Resolution (Å) | 3.2 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (6HLP) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | |||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 67 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | |
| Maximum Defocus (nm) | |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | cryoSPARC | |
| IMAGE ACQUISITION | SerialEM | 3.8 |
| CTF CORRECTION | cryoSPARC | |
| MODEL FITTING | PHENIX | |
| INITIAL EULER ASSIGNMENT | cryoSPARC | |
| FINAL EULER ASSIGNMENT | cisTEM | |
| CLASSIFICATION | RELION | |
| RECONSTRUCTION | cisTEM | |
| MODEL REFINEMENT | PHENIX | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 4135583 | |||