ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 6BEI | |
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| f_dihedral_angle_d | 4.783 |
| f_angle_d | 0.608 |
| f_chiral_restr | 0.049 |
| f_plane_restr | 0.004 |
| f_bond_d | 0.003 |
| Sample |
|---|
| Vaccinia virus scaffolding protein D13 with N-terminal 17 residue truncation, in its trimer sextet oligomeric state |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE-PROPANE |
| Sample Vitrification Details | 3 microliter sample volume was loaded onto a holey grid with additional graphene oxide film. 10 sec waiting time, 5 sec blotting time and blot force 0 ... |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 247311 |
| Reported Resolution (Å) | 3.9 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (6BEI) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | FLEXIBLE FIT | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 QUANTUM (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 50 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 500 |
| Maximum Defocus (nm) | 2500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | 105000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| IMAGE ACQUISITION | EPU | |
| CTF CORRECTION | CTFFIND | 4.1.9 |
| CTF CORRECTION | RELION | 3.1 |
| CTF CORRECTION | cisTEM | 1.0.0 |
| MODEL FITTING | UCSF Chimera | 1.13.1 |
| MODEL FITTING | Coot | 0.9.1 |
| MODEL REFINEMENT | PHENIX | 1.18 |
| INITIAL EULER ASSIGNMENT | RELION | 3.1 |
| FINAL EULER ASSIGNMENT | cisTEM | 1.0.0 |
| CLASSIFICATION | cisTEM | 1.0.0 |
| RECONSTRUCTION | cisTEM | 1.0.0 |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 303052 | D13 trimer sextet images were extracted from the images of tubular assembly (EMD-31953) by symmetry expansion and signal subtraction. | ||