Neuropeptide Y Y1 Receptor (NPY1R) in Complex with G Protein and its endogeneous Peptide-Agonist Neuropeptide Y (NPY)
ELECTRON MICROSCOPY
Refinement
| RMS Deviations | |
|---|---|
| Key | Refinement Restraint Deviation |
| f_dihedral_angle_d | 12.7913 |
| f_angle_d | 0.6327 |
| f_chiral_restr | 0.0454 |
| f_bond_d | 0.0037 |
| f_plane_restr | 0.0034 |
| Sample |
|---|
| Complex of Neuropeptide Y Y1 Receptor (NPY1R) with its endogeneous Peptide-Agonist Neuropeptide Y (NPY), G Protein and G-protein stabilizing antibody fragement (scFv16) |
| Sample Components |
| Neuropeptide Y Y1 Receptor (NPY1R) |
| nucleotide-free G-Protein heterotrimer |
| Neuropeptide Y |
| single-chain antibody Fv fragment (scFv16) |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | blot for 5 seconds before plunging |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 233117 |
| Reported Resolution (Å) | 3.2 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | POINT |
| Point Symmetry | C1 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (5ZBH, 6OS9, 6OS9, 6OS9, 6OS9) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | RIGID BODY FIT | ||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | FEI FALCON III (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 40 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1250 |
| Maximum Defocus (nm) | 3750 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 0.1 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | 75000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | Topaz | 0.2.4 |
| CTF CORRECTION | cryoSPARC | 3.2.0 |
| MODEL FITTING | PHENIX | 1.19.2-4158 |
| MODEL REFINEMENT | PHENIX | 1.19.2-4158 |
| INITIAL EULER ASSIGNMENT | cryoSPARC | 3.2.0 |
| FINAL EULER ASSIGNMENT | cryoSPARC | 3.2.0 |
| RECONSTRUCTION | cryoSPARC | 3.2.0 |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 1339224 | |||