ELECTRON MICROSCOPY
Starting Model(s)
| Initial Refinement Model(s) | |||
|---|---|---|---|
| Type | Source | Accession Code | Details |
| experimental model | PDB | 8AZ0 | |
| Sample |
|---|
| IAPP S20G plateau-phase fibril polymorph 2PF-L |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | FILAMENT |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | 6s blot |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | HELICAL |
| Number of Particles | 643005 |
| Reported Resolution (Å) | 2.2 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | |
| Refinement Type | |
| Symmetry Type | HELICAL |
| Axial Symmetry | C1 |
| Axial Rise | 2.41 |
| Angular Rotation | 178.82 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 (8AZ0) | ||||
| Refinement Space | REAL | ||||
| Refinement Protocol | AB INITIO MODEL | ||||
| Refinement Target | Correlation coefficient | ||||
| Overall B Value | 47 | ||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | FEI FALCON IV (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 39 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1000 |
| Maximum Defocus (nm) | 2400 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | 2.7 |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | FEI TITAN KRIOS AUTOGRID HOLDER |
| Nominal Magnification | 130000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| IMAGE ACQUISITION | EPU | |
| CTF CORRECTION | CTFFIND | |
| MODEL FITTING | Coot | 0.9 |
| INITIAL EULER ASSIGNMENT | RELION | 4.0 |
| FINAL EULER ASSIGNMENT | RELION | 4.0 |
| CLASSIFICATION | RELION | 4.0 |
| RECONSTRUCTION | RELION | 4.0 |
| MODEL REFINEMENT | PHENIX | 1.17 |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | 1978281 | Manually picked a subset of images to train a model for automatic fibril segment picking in crYOLO | ||