ELECTRON MICROSCOPY
| Sample |
|---|
| H. sapiens MCM bound to double stranded DNA and ORC1-6 |
| Sample Components |
| Double stranded DNA |
| H. sapiens MCM |
| H. sapiens ORC1-5 |
| H. sapiens ORC6 |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | PARTICLE |
| Vitrification Instrument | FEI VITROBOT MARK IV |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | SINGLE PARTICLE |
| Number of Particles | 182341 |
| Reported Resolution (Å) | 3.6 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | The here represented map is a composite map of the consensus refinement and the locally refined map encompassing the ORC1-5 complex. |
| Refinement Type | |
| Symmetry Type | POINT |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | |||||
| Refinement Protocol | |||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | The models of MCM2-7-ORC6 and ORC1-5 that were refined against the consensus refinement of the MCM-ORC complex and the locally refined ORC1-5, respect ... | ||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K2 SUMMIT (4k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 49.28 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 1000 |
| Maximum Defocus (nm) | 2500 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | 130000 |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| EM Software | ||
|---|---|---|
| Task | Software Package | Version |
| PARTICLE SELECTION | Topaz | 0.2.4 |
| IMAGE ACQUISITION | EPU | |
| CTF CORRECTION | CTFFIND | 4.1.10 |
| CTF CORRECTION | RELION | 4.0b-GPU |
| CTF CORRECTION | cryoSPARC | 3.3.2 |
| MODEL FITTING | UCSF ChimeraX | 1.6.1 |
| INITIAL EULER ASSIGNMENT | cryoSPARC | 3.3.2 |
| FINAL EULER ASSIGNMENT | cryoSPARC | 3.3.2 |
| RECONSTRUCTION | cryoSPARC | 3.3.2 |
| MODEL REFINEMENT | PHENIX | 1.21_5207 |
| MODEL REFINEMENT | ISOLDE | |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | ||||