KIF1A[1-393] P305L mutant AMP-PNP bound one and two heads bound states merged, in complex with a microtubule
ELECTRON MICROSCOPY
| Sample |
|---|
| KIF1A[1-393] P305L mutant - AMP-PNP one and two-heads-bound states (merged) in complex with a 15R microtubule |
| Specimen Preparation | |
|---|---|
| Sample Aggregation State | FILAMENT |
| Vitrification Instrument | |
| Cryogen Name | ETHANE |
| Sample Vitrification Details | |
| 3D Reconstruction | |
|---|---|
| Reconstruction Method | HELICAL |
| Number of Particles | 254197 |
| Reported Resolution (Å) | 3 |
| Resolution Method | FSC 0.143 CUT-OFF |
| Other Details | NUMBER OF ASYMMETRIC UNITS USED IS REPORTED IN "NUMBER OF SEGMENTS USED", DUE TO THE LOCAL PROCESSING STRATEGY EMPLOYED. |
| Refinement Type | |
| Symmetry Type | HELICAL |
| Axial Symmetry | C1 |
| Axial Rise | 5.64 |
| Angular Rotation | 168.09 |
| Map-Model Fitting and Refinement | |||||
|---|---|---|---|---|---|
| Id | 1 | ||||
| Refinement Space | |||||
| Refinement Protocol | |||||
| Refinement Target | |||||
| Overall B Value | |||||
| Fitting Procedure | |||||
| Details | |||||
| Data Acquisition | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Detector Type | GATAN K3 (6k x 4k) | ||||||||
| Electron Dose (electrons/Å**2) | 49.36 | ||||||||
| Imaging Experiment | 1 |
|---|---|
| Date of Experiment | |
| Temperature (Kelvin) | |
| Microscope Model | FEI TITAN KRIOS |
| Minimum Defocus (nm) | 810 |
| Maximum Defocus (nm) | 2210 |
| Minimum Tilt Angle (degrees) | |
| Maximum Tilt Angle (degrees) | |
| Nominal CS | |
| Imaging Mode | BRIGHT FIELD |
| Specimen Holder Model | |
| Nominal Magnification | |
| Calibrated Magnification | |
| Source | FIELD EMISSION GUN |
| Acceleration Voltage (kV) | 300 |
| Imaging Details |
| Image Processing | ||||
|---|---|---|---|---|
| CTF Correction Type | CTF Correction Details | Number of Particles Selected | Particle Selection Details | |
| PHASE FLIPPING AND AMPLITUDE CORRECTION | ||||