8VYV | pdb_00008vyv

Cryo-EM Structure of the BRAF K601E monomer


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d7.9749
f_angle_d1.3313
f_chiral_restr0.0734
f_plane_restr0.0092
f_bond_d0.0078
Sample
BRAF K601E - 14-3-3 complex
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification DetailsChameleon system (SPT Labtech)
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles27711
Reported Resolution (Å)5.86
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsResolution corresponds to the FSC 0.143 cut-off of the masked map
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement Protocol
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)51.55
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1400
Maximum Defocus (nm)4500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONLeginon
CTF CORRECTIONCTFFIND4
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION