9DFX | pdb_00009dfx

Cryo-EM structure of a SUR1/Kir6.2 ATP-sensitive potassium channel in the presence of Aekatperone in the closed conformation


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6BAA 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d7.875
f_angle_d0.3622
f_chiral_restr0.0385
f_plane_restr0.0027
f_bond_d0.0013
Sample
Kir6.2/SUR1 closed channel in complex with Aekatperone
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK III
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles78490
Reported Resolution (Å)4.1
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1 (7TYS)
Refinement Space
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)55
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)1000
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification81000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging DetailsTitan Krios with Falcon K3 at the Pacific Northwest National Lab
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC4.2.1
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONcryoSPARC4.2.1
MODEL FITTINGCoot
INITIAL EULER ASSIGNMENTcryoSPARC4.2.1
FINAL EULER ASSIGNMENTcryoSPARC4.2.1
CLASSIFICATIONcryoSPARC4.2.1
RECONSTRUCTIONcryoSPARC4.2.1
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION78490