9HIS | pdb_00009his

Extracellular components BamHIJK of the Bacteroides thetaiotaomicron BAM machinery


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
in silico modelAlphaFoldAF-Q8A1P7-F1 
in silico modelAlphaFoldAF-Q8A0S2-F1 
in silico modelAlphaFoldAF-Q8A1D9-F1 
in silico modelAlphaFoldAF-Q89ZS0-F1 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d9.022
f_angle_d0.788
f_chiral_restr0.053
f_plane_restr0.005
f_bond_d0.004
Sample
Extracellular components BamGHIJ of the Bacteroides thetaiotaomicron BAM complex
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles48834
Reported Resolution (Å)3.28
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value58
Fitting Procedure
DetailsAlphaFold2 models were docked using Phenix.
Data Acquisition
Detector TypeFEI FALCON IV (4k x 4k)
Electron Dose (electrons/Å**2)35
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification165000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION2266553