9I62 | pdb_00009i62

CryoEM structure of a RAD51 D-loop


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d14.888
f_angle_d0.441
f_chiral_restr0.039
f_bond_d0.006
f_plane_restr0.003
Sample
Complex of RAD51 pre-synaptic filament with donor DNA.
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification Instrument
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles102679
Reported Resolution (Å)2.64
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement Space
Refinement ProtocolOTHER
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)48.1
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)900
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
CTF CORRECTIONcryoSPARC4.4.1
MODEL FITTINGCoot0.9.8.94
INITIAL EULER ASSIGNMENTcryoSPARC4.4.1
FINAL EULER ASSIGNMENTcryoSPARC4.4.1
RECONSTRUCTIONcryoSPARC4.4.1
MODEL REFINEMENTPHENIX1.21.2_5419
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details